Model No:XS/CPR300S
Function Distinction: I standard configuration, A O O optional configuration
Model Type Function Function Features Configuration Content
XS/CPR300S CPR I Manikin. Controller
XS/CPR300S—A CPR I A Manikin. Controller with lithium battery
XS/CPR300S—G CPR IAO Manikin. Controller with lithium battery and Remote
XS/CPR300S—H CPR and Nursing IAOO Manikin. Controller with lithium battery and Remote and Nursing module
Executive standard: American heart association (AHA) 2012 international guidelines for cardiopulmonary resuscitation (CPR) &
CPR Manikin Function:
*The pupil adopts the LCD screen to simulate the state of pupil narrowing, normal and dilation. Under the state of rescue, the pupil dilated and the pupil narrowed and restored to light emission after rescue.
i The joints of the simulated human upper limbs can move freely. (Before and after spin, stretch, stretch, spin in, spin out) The wrist and elbow joints can be flexion and extension. Can practice patient handling
i Equipment fault self—test function: after starting the machine, the equipment will automatically enter the self—test program to check whether the equipment has faults
*The key operation adopts fault—tolerant technology k The chest cage is newly added to detect insufficient rebound
Manikin vital signs:
1) Initial state: No pulsating carotid artery, simulating dilated pupil
2) In the process of pressing; Manikin carotid artery passive pulsation, pulse frequency and compression frequency consistent
3) After successful rescue; Carotid artery beating autonomously, simulating pupil constriction and recovery of light reflex
IStandard airway can be opened and the airway indicator light is on IArtificial hand chest compressions and artificial respiration can be performed
IManual chest compressions:
1. Dynamic barcode indicator shows the depth of compression: the correct depth of compression (5 -6cm area) is displayed by
the green bar code, the depth of compression is not enough (less than 5cm) is shown by the yellow bar code, and the depth of compression is too deep (more than 6cm) is shown by the dynamic feedback ofthe movement ofthe red bar code indicator
2. LCD count and frequency display; Keep detailed records of the specific reasons for wrong pressing (too much pressing force, too little pressing force, wrong pressing position, too fast pressing frequency, too slow pressing frequency, etc.)
IArtificial mouth—to—mouth breathing (blowing):
1. The dynamic bar code indicator displays the tidal volume: the tidal volume blown in is correct (500ml~600ml—1000ml), and the
tidal volume blown in is too small or too large, and the tidal volume moved by the bar code yellow or red indicator respectively
2. Liquid crystal counting display: the specific causes of air blowing errors are recorded in detail (according to excessive air blowing volume, air blowing into the stomach, air blowing force is too small, and the number of correct air blowing) IRatio of compressions to breaths: 30:2 (single or double) IOperating cycle: 30 effective compressions and 2 manual blows, 30:2 5—cycle CPR IThree operation methods: CPR training, simulation test and practical test.